Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 1775 of 1775

Ability to modify 'Rational Method Frequency Adjustment Factor' for a specific catchment or range of catchments.

Currently there is only an option to add Rational Method Frequency Adjustment Factors for the entire storm, which affects all catchments. Our GDOT standards require modification of the factor for only C values less than 0.6.
about 3 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Update the Minnesota M1-6M, M1-6a and M1-X4 county shields for 3-digits

MnDOT wants to start using wider 3-digit sizes (22.5"x18", 30"x24" & 45"x36") for some of the county shields within the Minnesota standard in OpenRoads SignCAD. The wider 3-digit sizes are needed for the M1-6M and M1-6a blue pentagon county sh...
8 months ago in OpenRoads SignCAD / Workspace 0 Planned

Compare real data from a tunnel with its theoretical corridor

Hello. We're building a tunnel and need OpenTunnel to be able to compare the actual data from the constructed tunnel (recorded via scanning) with the theoretical data from the designed tunnel corridor. There are other programs that do this: Istram...
8 months ago in OpenTunnel Designer 0 Needs review

Allow Vertical Geometry Stationing (Profile Annotations) to Reflect Correct Horizontal Chord Definition Stationing

This would be useful for designers working on a project in which chord definition is the client's standard. Currently OpenRail does not correctly annotate the stationing in our profile sheets. The stationing displayed by OpenRail is correct in arc...
about 3 years ago in Annotation 1 Future consideration

Convert smart civil annotation to plain text

The ability to easily convert smart civil annotations to plain text will make it much easier to share annotations with other disciplines in DWG format. Also, sometimes we just do not want smart annotations within our drawings. Currently have to do...
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Horizontal and vertical regression values displayed in mm

Reporting horizontal slues and vertical lift/lowers interactively in the plan or profile model always displays as per the working unit, which I have set to metres. It would be useful to display these values in millimetres
about 3 years ago in Regression Analysis 0 Planned

Export to DWG: Improve and SIMPLIFY

Nowadays, it`s very, very and I can`t stress this enough, difficult to generate a dwg deliverable package for clients. Our market (Brasil) is dominated by AutoDesk, so dwg is a standard. We work on infrastrucure and have some really complex plan l...
over 2 years ago in All Other / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

camber at .1xCLBRG span in LEAP Concrete

Add an option to get camber given at 10th points on the clbrg span instead of the precast span. beams are being set at a certain elevation at CLBRG so the camber up from CLBRG is what we need to design geometry around, not camber up from end of pr...
4 months ago in Analytics / OpenBridge Designer 0 Future consideration

ORD DU File Recovery Tools

ORD DU File recovery tools would be extremely handy when dealing with support issues. I've had to deal with a support ticket where the file is crashing upon opening several times now, and being able to run some tools outside of ORD would be extrem...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Future consideration

Surface Templates- Option to create top 3D linear element

Currently, when a surface template is applied there is not a 3D linear element created for the top linear feature. It would be useful to have the option to create the top 3D linear element.
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration