Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Civil Product Ideas

Showing 1711 of 1711

Annotation Group Definition Copied to Active File when Used

When labeling civil geometry (alignments for example), whichever annotation group that is utilized is copied from the DNGLIB and saved with the active DGN. This is only the case when the geometry being annotated is stored within the active DGN, no...
8 months ago in Drawing Production / OpenRail Designer / OpenRoads Designer / Workspace 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
8 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
8 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add tool to import .prj settings and convert to .dty

This would save time and take out any guesswork for those needing to build custom coordinate systems using settings from a .prj.
over 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ability to change civil labeler border sizes

The borders that can be used for the civil labeler tool are different sizes. The ability to modify the sizes would help in adjusting the size based on the user needs. The dimension styles have this ability for the symbols used around the text.

For steel beams- When we create stiffeners and use them in cross frame definition, regardless of the method used, the stiffener tables when opened default to the first stiffener in the OBM library rather than the stiffener used in cross frame definition

Currently when we create a new stiffener and then when we create cross frames using those stiffeners, they don't show up when you open stiffener definition after creating cross frames (the first stiffener definition within the selection is shown)
8 months ago in OpenBridge Modeler 0 Needs review

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
8 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Export pier or abutment templates to Functional Component

Often times a small edit is needed to make an existing abutment or pier template match project standards. It is tedious to create a Functional Component from scratch for small edits. It would be helpful to have a tool or button to export a templat...
8 months ago in Modeling 0 Future consideration

Add option to center cross sections on sheet

Add option to place a single column of sections per sheet and to center all the cross sections on the sheet.
almost 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Ability to superscript and underline the decimal digits for spot elevation annotation

Currently it is not possible to format only the decimal digits of the annotation. The user wants to annotate the spot elevation in a custom format where the decimal units are having superscript and the underline. The option from DIN Dimensioning o...
over 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration