Many times, we have conduits/pipes that simply daylight a surface and drain on to the ground or into a pond. Please add the ability to place conduit/pipes "Without" the need of a Node. I understand that we can create a sort of null point/node that...
DU conduits external wall controled by Feature Symbology
We have the option to define a template to pipes external walls, but only through the feature definition. For all other elements of the pipe, OR allows for feature symbology. From my experience, symbologys work better and are more constant.
For large projects, we need the ability to have multiple engineers working on the hydraulic model. We can achieve this by splitting the pipe network into multiple files and creating catchments in separate files. Doing so causes us to lose the abil...
Add support for slope manipulator in profile when the "Use Construction Length and Slop" Preference = True
when the "Use Construction Length and Slope" Preference = True", in the profile view the slopes can not be edited. c If the "Use Construction Length and Slope" Preference is set to False, We can edit the slope value directly in the profile. Please...
When starting a DU, OpenRoads creates a whole DU project inside the file and brings a lot of hidroly/hidraulic properties with it. That's fine if the goal is to run an analysis. But what if I just want to model a whole network and never run it? Di...
Separate 3D line and 3D object for pipes to different levels.
In Drainage & Utilities, the 3D line and the 3D object for a pipes(conduit/link) is placed on same level. It would be great to have them on different levels - also because it can be a demand from from clients in Denmark, that the line is place...
When stepping through model builder there is an option to set the units that are to be used in the design file; however, when the property is set in the field mappings, it does not automatically default to what was selected on a previous screen. T...
There needs to be an option to import utilities from LandXML with the option to specify the import units. I have sewer information from a utility in LandXML format, but the units need to be set to US Survey Feet. Using the import from LandXML clas...
Automate the assignment of a node's sump offset based on largest connecting pipe's wall thickness
We are looking for a workflow where the Sump depth value can be set to the thickness of the "largest pipe" connected to a node. When the user places a node, if there is an option to set the sump depth to the thickness of the pipe, then it would au...